Important Safeguards/Conventions
This appliance is designed for commercial use. Any servicing other than cleaning and preventive maintenance
should be performed by an authorized Wilbur Curtis service technician.
•DONOTimmersetheunitinwateroranyotherliquid
•Toreducetheriskofreorelectricshock,DONOTopenservicepanels.Nouserserviceableparts
inside.
•Keephandsandotheritemsawayfromhotsurfacesofunitduringoperation.
•Nevercleanwithscouringpowders,bleachorharshchemicals.
Symbols
WARNINGS – To help avoid personal injury
Important Notes/Cautions – from the factory
Sanitation Requirements
YourIntelliFreshbrewerisFactoryPre-SetandReadytoGo…RightfromtheBox.
FollowingaretheFactorySettingsforIntelliFreshbrewer:
•BrewTemperature=200°F •WaterBypass=OnLARGE&MEDIUMbrewonly
•BrewVolume=Large-Medium-Small •EnergySaveMode=Off
•QualityTimer=120Minutes
SystemRequirements:
•WaterSource20–90PSI(MinimumFlowRateof1GPM)
•Electrical:Seeattachedschematicforstandardmodelorvisitwww.wilburcurtis.comforyourmodel.
SETUPSTEPS
Theunitshouldbelevel(lefttorightandfronttoback)andlocatedonasecurecountertop.Connectawater
linefromthewaterltertothebrewer.
NOTE:Awaterltrationsystemmustbeusedtomaintainatrouble-freeoperation.(Inareaswithextremely
hardwater,wesuggestthatasedimentaryandtaste&odorlterbeinstalled.)Thiswillprolongthelifeofyour
brewingsystemandenhancecoffeequality.
1.A3/8”Flarex3/8”Malepipeelbowissuppliedwiththebrewerforwaterlineconnection.Usetubingsized
sufcientlytoprovideaminimumof1.0GPM.
2.Connecttheunittoanappropriateelectricalpowercircuit.
3.Turnonthetoggle(STANDBY/ON)switchbehindtheunit.Theheatingtankwillstarttoll.Whenthewater
levelinthetankrisestothecorrectvolume,theheatingelementswillenergizeautomatically.Withthe
IntelliFreshbrewer,thereisnodangerofelementburnoutcausedbyoverheatinganemptytank.
4.Theheatingtankwillrequire20to30minutestoreachoperatingtemperature(200°F),indicatedwhen
READYTOBREWisdisplayedontheLCDscreen.
5.Priortobrewing,dispense12ouncesofhotwaterthroughthehotwaterfaucet.
6. Brewacycleofatleast12ounces,topurgethewaterlinesofanyairthatmaybetrappedafterlling.
NSF International requires the following water connection:
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) so that the ma-
chine can be moved for cleaning underneath.
2. Insomeareasanapprovedbackowpreventiondevicemayberequiredbetweenthebrewerand
the water supply.
Wilbur Curtis Company, inC.
Models
GEMTIF
GEMSIF
GEM3IF
ServiceManual–GeminiIntelliFreshBrewer
CAUTION: DO NOT
connect this brewer to hot
water. The inlet valve is
not rated for hot water.
CAUTION: Please use
this setup procedure
before attempting to use
this brewer. Failure to follow the
instructions can result in injury or the
voiding of the warranty.
IMPORTANT: Equipment
to be installed to comply
with applicable federal,
state, or local plumbing/electrical
codes having jurisdiction.
FOR THE LATEST SPECIFICATIONS AND INFORMATION GO TO WWW.WILBURCURTIS.COM
ISO9001:2008
Wilbur Curtis Company
Montebello,CA90640
Tel:(323)837-2300
www.wilburcurtis.com
Seitenansicht 0
1 2 3 4 5 6 ... 17 18

Inhaltsverzeichnis

Seite 1 - Wilbur Curtis Company, inC

1Important Safeguards/ConventionsThis appliance is designed for commercial use. Any servicing other than cleaning and preventive maintenance should be

Seite 2 - SATELLITE

10Illustrated Parts List GEMSIF 1 2 3 4 5 6 7 8 9 9A 9B1011121314151617181920212223242526272829303132333435363738394041GEM3IFWC-58117WC-371

Seite 3 - CLEANING

1123456171011121316181989A20151417AIllustrated Parts List GEM3IF

Seite 4 - GEM INTELLIFRESH

12DescriptionIndexNºPart Nº* SUGGESTED PARTS TO STOCKIllustrated Parts List GEM3IFA daily routine of cleaning the GEM3IF Satellite will maintain the a

Seite 5 - Program Menus GEMIF Brewer

135200760023.634.5Electrical SchematicGEMTIF

Seite 6

14Electrical SchematicGEMSIF(-10Only)

Seite 7

15Electrical SchematicGEM3IF

Seite 8

16SHOWING WC-37259BREW CONE ASSEMBLY.125”(.3 cm).25”(.6 cm)1.0”(2.5 cm)30.5”(77.5 cm)4.0”(10.0 cm)5.375”(13.7 cm)7.75”(19.7 cm)11.75(29.8 cm)11.25”(28

Seite 9

17This Page Intenionally Left Blank

Seite 10 - Illustrated Parts List

ECN 12835 . 12/27/[email protected] 12640 . 9/30/[email protected] 12400 . 6/15/10 @ 12.7edr 7091 . 3/23/10 @ 12.2Printed in U.S.A. 12/10 . F-3691 . rev CWILBUR

Seite 11

2GEMINI IF BREWERSATELLITEUCM CONTROLIF CONNECTORINTELLIFRESHFUNCTION&FEATURESThe IntelliFresh system is a method of storing coffee to maintain

Seite 12 - CLEANING THE GEM3IF SATELLITE

3ERROR MESSAGE DESCRIPTION CAUSE(900) 000-0000 EXT (0000)Water Level ERR.Fill run error/OverflowThe fill solenoid has either run formore than 10 minut

Seite 13 - Electrical Schematic

4CurtisCurtisReadyEnteringProgramming ModeEnter Code- - - -Program Menus<-- Select -->Global Recipes<-- Select -->Gourmet STD<-- S

Seite 14 - GEMSIF(-10Only)

5Program Menus GEMIF BrewerProgram MenusTemperatureEnergy Save ModeBrew Count OdomGlobal RecipesBanner NameAccess CodeService CallMaster ResetCold Bre

Seite 15

6Program Menus GEMIF BrewerP-MaintenanceBrew By TimeBrew By VolumeDispl. Brew TimePre-infusionPulse BrewBy-PassModel SelectP-Maintenance(Factoryset

Seite 16 - Rough-In Drawings

71234532678910111242133914381516171819434445202122303125262327242829333435413640537Illustrated Parts List GEMTIF

Seite 17

8 1 2 3 4 5 6 7 8 8A 9101112131415161718192021222324252627282930313233343536373839404142434445GEM3IFWC-37121*WC- 442WC-2977-101WC- 844-101*

Seite 18 - Product Warranty Information

9567891011121314353615161718192021222324252627282930313233123434373839407Illustrated Parts List GEMSIF

Kommentare zu diesen Handbüchern

Keine Kommentare